Home   »   Produk   »   Timers   »   Omron Product   »   Digital Timers
 
 

Digital Timers H5CZ

 
 
 

Untuk memesan, silahkan tekan tombol ORDER. Anda bisa memesan barang secara Online.

 

Anda juga bisa memesan via telephone. Silakan hubungi sales consultant, Hotline kami di, (021) 8690 6777 sales Consultant kami akan menjelaskan detail produk dan harga terbaru. atau email ke alamat sales@automationindo.com

 

 

Digital Timers H5CZ

Easy to Use and Easy to Read.

 

 

Features :

Basic Features

Better Readability

Character Height of 10 mm with a Wide Viewing Angle.

 

2640_fe_1.jpg

 

 

The Easiest Operation

Operation is simplified by the Up/Down Keys for each digit on 4-digit.

 

2640_fe_2.jpg

 

Safety and Reliability

Isolated Power Supply and Input Circuits *1

Power supply circuit and input circuits are isolated for safety and reliability.

Previous non-isolated timers had wiring restrictions and could be damaged if wired incorrectly. The H5CZ removes these worries.

 

2640_fe_3.jpg

*1.H5CZ with 100 to 240-VAC specifications.

 

 

Set Value Limit

You can set an upper limit for the set value to prevent unexpected operation of output devices caused by setting mistakes.

 

2640_fe_4.jpg

 

 

Output Counter

The output counter counts the number of times the output turns ON (alarm display, count monitoring, count in increments of 1,000). This counter is useful in managing the service life of the Timer or the load.

 

Other Features

Models with Instantaneous Contact Output

Models with instantaneous contact outputs have been added for use with self-holding circuits and as auxiliary relays. These models are also convenient when replacing analog timers.

Waterproof, Dust-proof Structure (UL508 Type 4X and IP66)

Worry-free application is possible in locations subject to water.

Note:When the Y92S-29 Waterproof Packing is used.

Key Protection

Select from any of seven protection patterns. Use the best one for the application.

New Modes

Modes, such as a stopwatch mode (Mode S), have been added.
Select any of 15 modes.


 

 

Specifications :

Ratings :


Models H5CZ-L8[]
Ratings Power supply voltage *1 100 to 240 VAC 50/60 Hz
12 to 24 VDC/24 VAC 50/60 Hz
Operating voltage
fluctuation range
85% to 110% of rated supply voltage (90% to 110% at 12 to 24 VDC)
Power consumption Approx. 6.2 VA at 100 to 240 VAC, Approx. 5.1 VA/2.4 W at 24 VAC/12 to 24 VDC *2
Mounting method Flush mounting, Surface mounting, DIN track mounting
External connections 8-pin socket
Degree of protection IEC IP66, UL508 Type 4X (indoors) for panel surface only and when Y92S-29 Waterproof Packing is used
4 digits
Digits
Time ranges 0.001 s to 9.999 s, 0.01 s to 99.99 s, 0.1 s to 999.9 s, 1 s to 9999 s, 1 s to 99 min 59 s
0.1 m to 999.9 min, 1 min to 9999 min, 1 min to 99 h 59 min, 0.1 h to 999.9 h, 1 h to 9999 h
Timer mode Elapsed time (Up), Remaining time (Down) (selectable)
Inputs Input signals Signal, Reset
(no inputs on models with instantaneous contact outputs)
Input method No-voltage Input
ON impedance: 1 kΩ max. (Leakage current: 12 mA when 0 Ω )
ON residual voltage: 3 V max.
OFF impedance: 100 kΩ min.
Signal, reset Minimum input signal width: 1 or 20 ms (selectable, same for all input)
Reset system Power reset (depending on output mode), External reset, Manual reset, Automatic reset (depending
on output mode)
Power reset Minimum power-opening time: 0.5 s (except for A-3, b-1, F, ton-1, and toff-1 mode)
Reset voltage 10% max. of rated supply voltage
Sensor waiting time 250 ms max. (Control output is turned OFF and no input is accepted during sensor waiting time.)
Output Output modes A: Signal ON Delay I, A-1: Signal ON Delay II, A-2:
Power ON Delay I, A-3: Power ON Delay II, b:
Repeat Cycle 1, b-1: Repeat Cycle 2, d: Signal
OFF Delay, E: Interval, F: Cumulative, Z: ON/OFF-
duty-adjustable flicker, S: Stopwatch, toff: Flicker
OFF Start 1, ton: Flicker ON Start 1, toff-1:
Flicker OFF Start 2, ton-1: Flicker ON Start 2


Models with Instantaneous Contact Outputs
A-2: Power ON Delay I, b: Repeat Cycle 1,
E: Interval, Z: ON/OFF-duty-adjustable flicker,
toff: Flicker OFF Start 1, ton: Flicker ON Start 1
One-shot output time 0.01 to 99.99 s
Control output 5 A at 250 VAC/30 VDC, resistive load (cos =1)
Minimum applied load: 10 mA at 5 VDC (failure level: P, reference value)
Display method *3 LCD; Present value: 10-mm-high characters
Set value: 6-mm-high characters
Memory backup EEPROM (overwrites: 100,000 times min.) that can store data for 10 years min.
Operating temperature range -10 to 55°C (-10 to 50°C if counters are mounted side by side) (with no icing or condensation)
Storage temperature range -25 to 70°C (with no icing or condensation)
Operating humidity range 25% to 85%
Front panel color Light gray (5Y7/1)

 

*1.Do not use the output from an inverter as the power supply. The ripple must be 20% maximum for DC power.

*2.Inrush current will flow for a short time when the power supply is turned ON.
Inrush Current (Reference Values)

 

Voltage Applied voltage Inrush current (peak value) Time
100 to 240 VAC 264 VAC 5.3 A 0.4 ms
12 to 24 VDC/24 VAC 26.4 VAC 6.4 A 1.4 ms
26.4 VDC 4.4 A 1.7 ms

 

*3.The display is lit only when the power is ON. Nothing is displayed when power is OFF.

 

Characteristics


Accuracy of operating time and
setting error (including
temperature and voltage influences)
Power-ON start: ±0.01% ±50 ms max. (See note)
Signal start: ±0.005%±0.03 ms max. (See note)
If the set value is within the sensor waiting time at startup the control output of the H5CZ will
not turn ON until the sensor waiting time passes.
Note: The values are based on the set value.
Insulation resistance 100 MΩ min. (at 500 VDC) between current-carrying terminal and exposed non-current-
carrying metal parts, and between non-continuous contacts
Dielectric strength 2,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and non-current-
carrying metal parts
2,000 VAC, 50/60 Hz for 1 min between power supply and input circuits for all models except
H5CZ-[]D
2,000 VAC, 50/60 Hz for 1 min between control output, power supply, and input circuits
1,000 VAC, 50/60 Hz for 1 min between non-continuous contacts
Impulse withstand voltage 3 kV (between power terminals) for 100 to 240 VAC, 1 kV for 24 VAC/12 to 24 VDC
4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts) for
100 to 240 VAC 1.5 kV for 24 VAC/12 to 24 VDC
Noise immunity ±1.5 kV (between power terminals) and ±600 V (between input terminals), square-wave noise
by noise simulator (pulse width: 100 ns/ 1 μs, 1-ns rise)
Static immunity Malfunction: 8 kV
Destruction: 15 kV
Vibration resistance Destruction 10 to 55 Hz with 0.75-mm single amplitude each in three directions for 2 h each
Malfunction 10 to 55 Hz with 0.35-mm single amplitude each in three directions for 10 min each
Shock resistance Destruction 300 m/s2 in three directions, three cycles
Malfunction 100 m/s2 in three directions, three cycles
Life expectancy Mechanical 10,000,000 operations min. (under no load at 1,800 operations/h and ambient temperature of
23°C)
Electrical 100,000 operations min. (5 A at 250 VAC, resistive load at 1,800 operations/h and ambient
temperature of 23°C) *
Weight Approx. 105 g (Timer only)

 


*Refer to Life-test Curve.

 

 

Life-test Curve (Reference Values)

 

2640_sp_4.gif

 

A maximum current of 0.15 A can be switched at 125 VDC (cosφ =1) and a maximum current of 0.1 A can be switched if L/R is 7 ms. In both cases, a life of 100,000 operations can be expected.

 

 

I/O Functions

For details, refer to the timing charts on Data Sheet.

 

Inputs * Start signal Normally functions to start timing.
In modes A-2 and A-3, disable timing. In mode S, starts and stops timing.
Reset Resets present value. (In elapsed time mode, the present value returns to 0; in remaining time mode,
the present value returns to the set value.)
Count inputs are not accepted and control output turns OFF while reset input is ON.
Reset indicator is lit while reset input is ON.
Outputs Control output (OUT) Outputs take place according to designated operating mode when timer reaches corresponding set value.

 

*The H5CZ-L8E[] does not have an input.